Pratt Industrial butterfly valve data you can paste straight into your plans
Pratt Industrial butterfly valves, laid out for the people drawing and specifying mission critical work: data centers, hospitals, labs and other critical facilities. Sizes, pressures, materials, Cv, model strings, a Division 23 guide spec and a basis of design paragraph. One click copies each one. Nothing to sign up for.
For specification writers
Section 23 05 23, General-Duty Valves for HVAC Piping. Name Pratt Industrial as the basis of design early, while the mechanical spec is still open. The paragraphs to paste are right below. Copy them with one click.
Submittal package
Cut sheets, Cv tables, materials and test certificates. Design standard is API 609 on all three series, and every valve is leak tested at rated pressure per API 598.
Substitutions
The guide spec names the manufacturer with “or approved equal,” so your section stays open.
Why early
Naming a basis of design early, while the mechanical spec is still open, keeps your submittal and schedule simple.
The paragraph to paste
Naming a basis of design early keeps the submittal, the schedule and the replacement parts simple. These blocks are written to drop into a project specification. Edit them to fit your project.
BASIS OF DESIGN: Butterfly valves for chilled water, condenser water and liquid cooling loops shall be Pratt Industrial, Emporia, Kansas. Series BF or OS (wafer or lug) for ANSI 125/150 flanged piping, and Series HP (double offset) for ANSI Class 150, 300 and 600 piping as required by pressure and service. Equivalent products by other manufacturers may be submitted for approval by the Engineer.
Manufacturer: Pratt Industrial Product: Butterfly valves, BF, OS and HP Series Sizes: 1 to 72 inches Standards: API 609, API 598, ISO 5211, ASME B16.1 / B16.5 Location: Emporia, Kansas (warehouse and machine shop) Web: prattindl.com Customer service: 1.800.423.1323
SECTION 23 05 23 - BUTTERFLY VALVES FOR HVAC AND CRITICAL COOLING PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section includes resilient seated and double offset butterfly valves for chilled water, condenser water, glycol and liquid cooling piping. 1.2 REFERENCES A. API 609, Butterfly Valves: Double-flanged, Lug- and Wafer-type. B. API 598, Valve Inspection and Testing. C. API 607, Fire Test for Quarter-turn Valves (HP Series with fire-safe seat). D. ASME B16.1 and B16.5, Flanges. ASME B16.34, Valves. E. ISO 5211, Actuator Attachment. ISO 5752, Face-to-Face Dimensions. 1.3 SUBMITTALS A. Product data, dimensions, materials of construction, pressure ratings and Cv data. B. Actuator and accessory data where valves are automated. 1.4 QUALITY ASSURANCE A. Each valve shall be leak tested in the factory at its rated pressure per API 598. PART 2 - PRODUCTS 2.1 MANUFACTURER A. Pratt Industrial, Emporia, Kansas, or approved equal. 2.2 WAFER AND LUG BUTTERFLY VALVES, 1 TO 48 INCHES (BF, OS) A. Service: Lug valves shall be designed for installation between ANSI 125/150 flanges. Wafer valves shall be designed for installation between ANSI 125/150 flanges [and PN 10 and PN 16 flanges (BF)]. All valves shall be capable of bi-directional, end of line, bubble tight service to rated pressure and shall be rated to full vacuum service. Design standard: API 609 Category A. B. Pressure rating: [BF: 250 psi 2 to 12 inches, 150 psi 14 to 24 inches] [OS: 200 psi 1 to 12 inches, 150 psi 14 to 48 inches]. C. Body: One piece ductile iron, ASTM A536 Grade 65-45-12, laying length per ISO 5752, flange connection per ASME B16.1/B16.5. D. Disc: Ductile iron ASTM A536 Grade 65-45-12 with ENP plating [or nylon 11 coating] [CF8M stainless steel (BF)] [304 stainless steel (OS)] [aluminum bronze]. Disc shall accommodate an upper and lower shaft with a thin center profile giving higher Cv values combined with strength. E. Shaft: [Heat treated 416 stainless steel (BF)] [Heat treated 410 stainless steel (OS)]. Two shafts, upper and lower. The upper shaft shall have positive engagement in the disc through an internal square drive and be retained by the body top cap. Shaft shall be blowout proof per API 609 with a secondary stem journal seal preventing leakage to atmosphere. F. Seat: [EPDM] [Buna-N] [Viton], field replaceable. Seat shall have three tongues (two on the side walls and one in the center bore) engaging three grooves in the body to prevent seat movement in a radial and axial direction. G. Shaft seals: Upper shaft seal shall be [self-adjusting V-type (BF)] [self-adjusting O-ring (OS)], suitable for pressure or vacuum service. Bottom end cap shall contain a captive O-ring creating a positive seal against external leakage. H. Bushings: [Two full length Nylatron bushings, upper and lower (BF)] [Three upper and one lower RTFE bushing (OS)]. I. Top flange: ISO 5211 for direct actuator mounting. J. Lug style valves shall be suitable for dead-end service. K. Operators: [Lever] [Worm gear] [Pneumatic actuator] [Electric actuator]. 2.3 DOUBLE OFFSET BUTTERFLY VALVES, 2 TO 72 INCHES (HP) A. Design: Double offset disc and shaft with a spherical sealing surface and a free-floating, pressure-assisted seat retained between the body and a retention ring. Bi-directional sealing with soft seat. API 609 Category B. B. Pressure class: [ASME Class 150, 285 psi, 2 to 72 inches] [Class 300, 740 psi, 2 to 48 inches] [Class 600, 1440 psi, 3 to 24 inches], suitable for installation between ASME B16.5 flanges. C. Body: [WCB carbon steel ASTM A216] [CF8M stainless steel ASTM A351]. Styles: [wafer] [lug] [short flanged] [long flanged] [butt-weld]. D. Disc: CF8M stainless steel ASTM A351. Shaft: One piece hardened 17-4 PH stainless steel, blowout proof. E. Seat: [PTFE] [RTFE] [MTFE] [316 stainless steel] [Inconel] [Fire-safe, tested to API 607]. F. Bearings: Full length upper and lower, 316 stainless steel impregnated with [PTFE] [graphite]. G. Packing: [Multi-layer PTFE cup and cone] [Die-formed graphite for metal seated and fire-safe valves], located below the bonnet for direct mounting of automation. H. Integrally cast travel stop and extended neck with a minimum 2 inch bonnet to flange clearance for insulation. I. Vacuum rated dead end and double dead end service: lug type only. J. Material test reports and test certificates available on request. PART 3 - EXECUTION 3.1 INSTALLATION A. Install valves with the disc partly open during flange bolting to protect the seat. B. Use the flange gasket and bolting recommended by the piping specification. Do not install additional gaskets on resilient seated valves. C. Verify disc swing clearance against the pipe inside diameter, reducers and fittings before installation. D. Support valves and actuators independently where weight requires. 3.2 FIELD QUALITY CONTROL A. Operate each valve fully open and closed to verify smooth travel and position indication before system flushing. B. Leak test with the piping system per Section 23 21 13. END OF SECTION 23 05 23
Pick a valve in 30 seconds
Almost every butterfly valve on a cooling loop is one of two designs. Resilient seated valves (BF and OS) seat into an elastomer ring. High performance double offset valves (HP) seat into a fluoropolymer seat set back behind the shaft. Start with the flange class and size of the line.
| Series | Design | Sizes | Pressure | Body | Good fit for |
|---|---|---|---|---|---|
| BF | Resilient seated, wafer or lug | 2″–24″ | 250 psi (2″–12″), 150 psi (14″–24″) | Ductile iron | Chilled water and condenser water isolation at ANSI 125/150 flanges |
| OS | Resilient seated, wafer or lug | 1″–48″ | 200 psi (1″–12″), 150 psi (14″–48″) | Ductile iron | The widest size range for mechanical rooms and large headers at ANSI 125/150 flanges |
| HP | High performance double offset | 2″–72″ | Class 150: 285 psi · Class 300: 740 psi · Class 600: 1440 psi | WCB carbon steel or CF8M stainless | CDU and technology cooling loops, glycol service, higher pressure classes, modulating duty |
Pressure at a glance
Every rating on one scale, 0 to 1500 psi. Blue is resilient seated (BF and OS). Orange is high performance (HP). Then check your own line below.
Resilient seated · BF and OS
High performance double offset · HP
BF Series
Rated 250 psi at 12″. Resilient seated, wafer or lug.
Open series data →FitsOS Series
Rated 200 psi at 12″. Resilient seated, wafer, lug or flanged.
Open series data →FitsHP Class 150
Rated 285 psi at 12″. Double offset, ANSI 150.
Open series data →FitsHP Class 300
Rated 740 psi at 12″. Double offset, ANSI 300.
Open series data →FitsHP Class 600
Rated 1440 psi at 12″. Double offset, ANSI 600.
Open series data →Flow capacity by size
Cv at full open for the size you pick. Higher Cv means less pressure drop across the valve.
Cv at full open
Full tables by degree of opening, 10° through 90°, are in each brochure. If a valve will do any control work, size against Cv at the position it will actually sit, not the full open number. A 12″ BF at 60° open is 2,799 against 9,245 wide open, roughly 30% of full capacity.
| Size | BF | OS | HP Cl 150 | HP Cl 300 | HP Cl 600 |
|---|---|---|---|---|---|
| 2″ | 206.4 | 115 | 88 | 88 | — |
| 4″ | 825.6 | 600 | 410 | 410 | 243 |
| 6″ | 1,858 | 1,579 | 1,060 | 995 | 630 |
| 8″ | 3,302 | 3,136 | 2,200 | 1,900 | 1,100 |
| 12″ | 9,245 | 8,250 | 4,700 | 4,100 | 2,700 |
| 16″ | 16,435 | 16,388 | 7,900 | 6,900 | 5,100 |
| 20″ | 25,680 | 27,908 | 13,800 | 12,600 | 7,800 |
| 24″ | 36,979 | 43,116 | 21,100 | 18,900 | 12,500 |
Series data, ready to copy
Each card has the facts engineers ask for first. The schedule row pastes as tab separated columns into a valve schedule or a spreadsheet.
BF Series
Resilient seated · wafer BF1 / lug BF2 · API 609 Cat. AA thin, high-flow disc on a two-piece shaft with full-length bushings. A three-point tongue-and-groove seat holds under high dead-end pressure and full vacuum.
- Sizes
- 2″ to 24″
- Pressure
- 250 psi 2″–12″ · 150 psi 14″–24″
- Body
- One piece ductile iron ASTM A536 65-45-12
- Disc
- Ductile iron with ENP plating or nylon 11, CF8M stainless, or aluminum bronze
- Shaft
- Heat treated 416 stainless, two shafts, blowout proof
- Seat
- EPDM, Buna-N or Viton, field replaceable
- Bushings
- Two full length Nylatron
- Flanges
- Wafer: ANSI 125/150, PN10, PN16 · Lug: ANSI 125/150 · B16.1 / B16.5 · ISO 5752
- Model string
- BF1-0208688 = wafer, 2″, ductile iron body, CF8M disc, 416 stem, EPDM seat
OS Series
Resilient seated · wafer OS1 / lug OS2 / flanged OS3 · API 609 Cat. AThe same tongue-and-groove seat design as the BF, in the widest size range of the three. Three upper bushings and one lower bushing reduce stem friction and torque.
- Sizes
- 1″ to 48″
- Pressure
- 200 psi 1″–12″ · 150 psi 14″–48″ · Viton rated 165 psi
- Body
- One piece ductile iron ASTM A536 65-45-12
- Disc
- Ductile iron with ENP plating or nylon, 304 stainless, or aluminum bronze
- Shaft
- Heat treated 410 stainless, two shafts
- Seat
- EPDM, Buna-N or Viton, field replaceable
- Bushings
- Three upper and one lower RTFE
- Shaft seal
- Self-adjusting O-ring, pressure or vacuum service
- Model string
- OS1-020-8CF8 = model, size, then body, disc, stem and seat codes
HP Series
Double offset · API 609 Cat. B · API 607 fire-safeA double offset disc with a spherical sealing surface and a free-floating, pressure-assisted seat. Fluoropolymer seat options, higher pressure classes, and sizes up to 72″.
- Sizes
- 2″ to 72″
- Pressure
- Class 150: 285 psi (2″–72″) · Class 300: 740 psi (2″–48″) · Class 600: 1440 psi (3″–24″)
- Body
- WCB (A216) carbon steel or CF8M (A351) stainless. Other alloys on request
- Disc
- CF8M (A351) stainless
- Shaft
- Hardened 17-4 PH stainless, one piece, blowout proof
- Seat
- PTFE, RTFE or MTFE standard, with 316 stainless, Inconel, metal and fire-safe options
- Body styles
- HP1 wafer · HP2 lug · HP3 short flanged · HP4 long flanged · HP5 butt-weld
- Standards
- ASME B16.34, API 607, API 598 (100% tested), MSS SP-68, ASME B16.10, ISO 5752, BS 5155
- Extras
- Gland packing below the bonnet so automation direct mounts, 2″ minimum neck clearance for insulation, integral travel stop. Test reports and MTRs on request
Materials and stainless options
Ductile iron and carbon steel are standard. Stainless is available on every series, so say it in the spec when the service calls for it. Stainless parts also change the pressure rating on some builds, so confirm with the manufacturer.
| Series | Body | Disc | Stainless options | |
|---|---|---|---|---|
| BF | Ductile iron A536 65-45-12 | Ductile iron ENP or nylon 11, CF8M stainless, aluminum bronze | CF8M stainless disc. Heat treated 416 stainless shaft | BF data |
| OS | Ductile iron A536 65-45-12 | Ductile iron ENP or nylon, 304 stainless, aluminum bronze | 304 stainless disc. Heat treated 410 stainless shaft | OS data |
| HP | WCB carbon steel (A216) or CF8M stainless (A351) | CF8M stainless | CF8M stainless body and disc, 17-4 PH stainless shaft, 316 stainless or Inconel seat options. Other alloys on request, including Alloy 20, Hastelloy C276, Monel and Duplex 2205 | HP data |
What they look like
Watch each valve open and close. The first two drawings look down the shaft. Closed, the disc blocks the pipe. Open, it turns to lie along the flow. The last two look down the pipe at the body styles. Product photos for every series are on the manufacturer series pages.
Resilient seated. The disc presses into an elastomer ring (EPDM, Buna-N or Viton) in the body.
Double offset. The shaft sits behind the disc, so the disc lifts away from the seat as it opens, and drags less. PTFE, RTFE, MTFE or metal seat.
Sits between two flanges. Lightest and most compact. Not for dead-end service.
Tapped bolt holes. Each flange bolts to the valve on its own, so it suits dead-end service.
Where the valves go in a cooling plant
A data center is a water plant with servers in it. A butterfly valve on a chilled water loop gets chosen during design, bought during construction, and stays where it is for as long as the building runs. Isolation and control points show up through every loop below. Final locations are always per system design.
Map of valve locations
- 1Cooling tower isolation
Supply and return at each tower cell, so one cell can come out of service. - 2Condenser water pump isolation
Suction and discharge of each pump. - 3Chiller condenser isolation
Lets a chiller be serviced while the others run. - 4Chiller evaporator isolation
Chilled water side of each chiller. Often paired with actuators for staging. - 5Chilled water pump isolation
Suction, discharge and check service around each pump. - 6Header sectionalizing
Splits the header so one section can be repaired without a shutdown. - 7Air handler isolation and control
Each CRAH or coil, with actuated control valves where needed. - 8CDU facility water isolation
Supply and return to each coolant distribution unit. - 9Technology loop isolation
Between the CDU and racks, with water-glycol service.
Typical layout for illustration. Real plants vary. BF and OS series cover most chilled and condenser water sizes, and HP series is available where the pressure class goes higher. Confirm sizes, ratings and materials against the current cut sheet for your project.
| Loop | Typical service | What matters |
|---|---|---|
| Chilled water, closed | Isolation at chillers, pumps, air handlers and headers. Balancing and control with actuation | Elastomer selection against treatment chemistry. Full vacuum rating |
| Condenser water, open | Isolation at towers, condensers and pumps. Basin and bypass | Open loop chemistry. Lug body where dead end service is required |
| CDU and technology cooling | Isolation and control on liquid cooling distribution, water-glycol | Fluoropolymer seat options. Higher pressure classes available |
| Waterside economizer | Changeover and isolation | Operating pressure and cycling frequency drive the choice |
| Makeup and facility water | Isolation on makeup, fill and drain | Standard trim per site water quality |
What a cut sheet does not tell you
The questions that come up most once a valve is on the drawing.
The disc swings past the face of the valve as it opens. Check the ØA and ØB dimensions against the pipe ID before committing a layout, especially next to a reducer, a fitting or lined pipe.
A 24″ BF lug is roughly 408 lbs bare. A 24″ HP Class 300 lug is roughly 1,005 lbs and Class 600 roughly 2,110 lbs. Add the actuator on top.
HP carries an extended neck with a minimum 2″ bonnet to flange clearance on all sizes. On BF and OS, check the E dimension against your insulation thickness.
All three series use an ISO 5211 top flange. BF also carries Kv industrial drilling and HP offers ISO drilling on request.
If a specific disc or seat material needs to arrive, it has to be in the model string. Each brochure has the ordering table.
1. Which positions modulate rather than isolate. 2. What is the actual fluid, since glycol percentage and water treatment drive elastomer selection and EPDM, Buna-N and Viton are not interchangeable. 3. Where dead end service is required, since a wafer body has no mechanical attachment to either flange and HP vacuum-rated dead end service is lug type only.
Five steps to a listed manufacturer
- Name a basis of designPaste the paragraph from the guide spec into Section 23 05 23 while the mechanical spec is open.
- Add to the approved listPut the manufacturer on the owner’s approved manufacturer list or master spec so every project inherits it.
- Attach the submittal dataCut sheets, Cv tables, dimensional data and suggested spec language are published for every series.
- Name a local distributorDistributors stock and ship across the country. Ask for the nearest one.
What a company needs for its approved list
Requirements vary by owner and engineer. Most ask for the items below. A manufacturer name and location is enough to start. A person’s name and a street address are not required to name a basis of design.
- Manufacturer name and location
- Product lines and model strings
- Design and test standards (API 609, API 598)
- Cut sheets and suggested specification language
- Cv data by degree of opening
- Dimensional data for wafer and lug
- Material test reports and test certificates (HP, on request)
- Distributor or local contact
- Company forms such as insurance, safety and tax, through supplier registration on request
MANUFACTURER INFORMATION FOR APPROVED MANUFACTURER LIST Manufacturer: Pratt Industrial Location: Emporia, Kansas. Warehouse and full-service machine shop, over 65,000 sq ft Customer service: 1.800.423.1323 Web: prattindl.com Products: Butterfly valves. BF Series (2 to 24 in), OS Series (1 to 48 in), HP Series double offset (2 to 72 in) Pressure: BF 250 psi (2-12 in) and 150 psi (14-24 in). OS 200 psi (1-12 in) and 150 psi (14-48 in). HP Class 150, 300 and 600 Standards: API 609, API 598, ISO 5211, ASME B16.1 / B16.5. HP also ASME B16.34 and API 607 Actuation: Lever, worm gear, pneumatic, electric Documents available: Cut sheets, suggested specification language, Cv tables and dimensional data. Material test reports and test certificates on request (HP) Submittal package requests: use the request form on the Valve Kit page
Where the valves come from
- Large sizes and actuated assemblies take more planning. Ask early.
- Ask about staged delivery on large jobs.
- Ask for the nearest distributor that stocks your series.
- Put the full model string on the submittal so the right disc and seat arrive.
Valves get planned last, and it shows
A lot of cooling plants are designed with the chillers, towers and CDUs settled first and the valves left as a line on a submittal. What we hear from the field is that this is where jobs slow down.
- Valves are bought after design, so the schedule has no room if the first choice is not available.
- The wrong seat material or disc is found at commissioning, when changing it costs the most.
- Actuator and top flange details get settled late, so automation waits on the valve.
- Large sizes and actuated assemblies take longer than people plan for.
- Owner-furnished valves arrive without a spec that tells the contractor which ones.
- Glycol percentage and water treatment are not checked against the elastomer until late.
Plan these early
- Name the manufacturerBasis of design in the spec, not “or equal” alone.
- Pick the designResilient seated or double offset, by pressure and duty.
- Check the fluidGlycol percentage and treatment drive the seat material.
- Settle the actuatorISO 5211 top flange keeps options open.
These are general observations from the field, not a survey. Valve selection and scheduling are always the responsibility of the engineer of record and the contractor.
Who is behind these valves
Pratt Industrial makes the BF, OS and HP butterfly valves on this page, built for chilled water, condenser water and liquid cooling loops. It is a Mueller Water Products brand, with product stocked and shipped across the United States.
- Made for the specGuide spec, basis of design, schedule rows and approved manufacturer text are all copy and paste on this page.
Related brands in the same family
- Singer Valve
Automatic control valves for pressure, level and flow. - Echologics
Acoustic leak detection and pipe condition assessment for water systems.
This page is an independent reference compiled from published product data. It is not an official Mueller Water Products or Pratt Industrial website.
Eco Business News is not owned or operated by Pratt Industrial or Mueller Water Products. Contributors may work for companies mentioned on this site. Confirm product details with the manufacturer before specifying.
Request cut sheets, spec language or a listing
Tell us what you are working on. Cut sheets, spec language and approved manufacturer list information for chilled water, condenser water, liquid cooling and critical facility valves. Your request goes to a Pratt Industrial representative.
BF Resilient seated butterfly valve, wafer (BF1) / lug (BF2) 2"-24" 250 psi (2"-12") / 150 psi (14"-24") Ductile iron A536 65-45-12 EPDM/Buna-N/Viton API 609 Cat A, API 598 ISO 5211 Pratt Industrial
OS Resilient seated butterfly valve, wafer (OS1) / lug (OS2) / flanged (OS3) 1"-48" 200 psi (1"-12") / 150 psi (14"-48") Ductile iron A536 65-45-12 EPDM/Buna-N/Viton API 609 Cat A, API 598 ISO 5211 Pratt Industrial
HP High performance double offset butterfly valve, HP1-HP5 2"-72" Cl150 285 psi / Cl300 740 psi / Cl600 1440 psi WCB A216 or CF8M A351 PTFE/RTFE/MTFE/316 SS/Inconel/fire-safe API 609 Cat B, API 607, API 598 ISO 5211 (ISO drilling on request) Pratt Industrial
Butterfly valves 2 to 24 inches shall be wafer or lug style, bi-directional, end of line, bubble tight to rated pressure and rated to full vacuum, designed to API 609 Category A and leak tested in the factory per API 598. Body one piece ductile iron ASTM A536 65-45-12. Disc ductile iron with ENP plating or nylon 11, CF8M stainless steel, or aluminum bronze. Shaft heat treated 416 stainless steel, two shafts, blowout proof, with secondary stem journal seal. Seat EPDM, Buna-N or Viton, field replaceable, with three tongue and groove connection points. Two full length Nylatron bushings. Pressure rating 250 psi for 2 to 12 inches and 150 psi for 14 to 24 inches. ISO 5211 top flange. Basis of design: Pratt Industrial BF Series.
Butterfly valves 1 to 48 inches shall be wafer, lug or flanged style, bi-directional, end of line, bubble tight to rated pressure and rated to full vacuum, designed to API 609 Category A and leak tested in the factory per API 598. Body one piece ductile iron ASTM A536 65-45-12. Disc ductile iron with ENP plating or nylon, 304 stainless steel, or aluminum bronze. Shaft heat treated 410 stainless steel, two shafts. Seat EPDM, Buna-N or Viton, field replaceable, with three tongue and groove connection points. Three upper and one lower RTFE bushing. Pressure rating 200 psi for 1 to 12 inches and 150 psi for 14 to 48 inches. ISO 5211 top flange. Basis of design: Pratt Industrial OS Series.
Double offset butterfly valves 2 to 72 inches shall have a spherical sealing surface and a free-floating, pressure-assisted seat, designed to API 609 Category B and ASME B16.34, tested 100 percent per API 598, and fire tested to API 607 where fire-safe seats are specified. Body WCB ASTM A216 or CF8M ASTM A351. Disc CF8M stainless steel. Shaft one piece 17-4 PH stainless steel, blowout proof. Seat PTFE, RTFE, MTFE, 316 stainless steel, Inconel or fire-safe. Gland packing below the bonnet, extended neck with 2 inch minimum insulation clearance. Ratings ASME Class 150 (285 psi), Class 300 (740 psi) and Class 600 (1440 psi). Basis of design: Pratt Industrial HP Series.
Size BF OS HP Cl150 HP Cl300 HP Cl600 2" 206.4 115 88 88 4" 825.6 600 410 410 243 6" 1858 1579 1060 995 630 8" 3302 3136 2200 1900 1100 12" 9245 8250 4700 4100 2700 16" 16435 16388 7900 6900 5100 20" 25680 27908 13800 12600 7800 24" 36979 43116 21100 18900 12500
Subject: Valve data request Project / location: Series needed (BF, OS, HP): Size range: Flange class / pressure: Service (chilled water, condenser water, liquid cooling): Files needed (cut sheets and series data): Reply to:
info@ecobusinessnews.com